QA of Xray Machine Specification

  • Material
  • Mild Steel, Powder Coated Finish, Lead Shielded
  • Condition
  • New & Recalibrated
  • Technology
  • Digital Radiography (DR), Computed Radiography (CR), Analog
  • Portable
  • Yes (Models Available), Trolley Mounted or Stationary
  • Light Source
  • Tungsten Filament, LED, Halogen
  • Pressure Range
  • Atmospheric Pressure 80 - 106 kPa
  • Operating Temperature
  • +5C to +40C
  • Humidity %
  • 90% Non-Condensing
  • Sensors Specification
  • Digital Flat Panel Detector, High Sensitivity X-Ray Sensor, 14 x 17 inch Surface Area
  • Indicator Specification
  • LED Indicator for Power, Status, X-Ray Exposure, Overheat Protection
  • Darkness Range
  • 0.2-2.5 Dmin to Dmax (Film Models)
  • Speed Range
  • 0.1 - 5 sec Exposure Time
  • Ray Frequency Range
  • 30 kHz - 100 kHz (High Frequency X-Ray Generator)
  • Exposure Time Range (in Sec)
  • 0.02-6.3 sec
  • Focus
  • 0.6/1.3 mm Dual Focus
  • Image System
  • Direct Digital Output, DICOM Compatible, Real-Time Display
  • Usage
  • Hospitals, Diagnostic Centres, Veterinary Purposes, Clinical, Industrial Applications
  • Power Source
  • 220V AC, 50Hz (Single/Three Phase Optional)
  • Power Consumption
  • 3 kW (depending on generator and model)
  • Working Voltage
  • 110/220V 10%
  • Dimension (L*W*H)
  • 1600 800 1800 mm (Typical, Model-Dependent)
  • Weight
  • 60-150 kg (Model Dependent)
  • X-ray Tube Type
  • Rotating Anode / Stationary Anode
  • Maximum Tube Voltage
  • 40-125 kV (model dependent)
  • Beam Limiting Device
  • Manual/Electric Collimator Available
  • Image Resolution
  • >3.5 lp/mm, 16-bit Gray Scale
  • Cooling System
  • Oil/Air Cooled X-ray Tube
  • Software Features
  • Automatic Image Processing, Optional PACS Integration
  • Connectivity
  • USB, LAN, Wireless (optional)
  • Standard Accessories
  • Hand Switch, Foot Switch, Grids, Cassette Tray, Dose Area Product Meter
  • Mounting
  • Floor, Wall, Ceiling Suspended (Model Options)
  • Patient Table
  • Radiolucent, Motorized/Manual Movement
  • Maximum Tube Current
  • 100-500 mA
  • Safety Features
  • Interlock System, Emergency Stop, Built-in Protection Circuits
 
 

About QA of Xray Machine



Highlighted as the ultimate solution for versatile imaging, our X-Ray Machine boasts top features with model-dependent tube voltage up to 125 kV and current up to 500 mA. Valued for its eminent image resolution (>3.5 lp/mm) and advanced 16-bit gray scale, this affordable unit integrates motorized or manual patient table movement and rotating or stationary anode tube. Equipped with powerful cooling, comprehensive safety systems, and distinguished connectivity, this valiant machine supports hospitals, clinics, veterinary centers, and industry. Options include digital, portable, ceiling, or floor mounting, fulfilling every application with elite precision.

Application & Usage Directions

The QA of our X-Ray Machine is prominent across various application media, optimally functioning in clinical and diagnostic settings, as well as veterinary and industrial environments. Use type varies from routine screenings to complex diagnostics, supported by clear operational guidance paired with manual, motorized, and software-controlled modes. Direction of use involves straightforward positioning on the radiolucent table and intuitive setup through either manual or electronic controls, ensuring efficient workflow and reliable results every session.


Export Markets, Sample Policy & Logistics Information

We are eminent exporters, manufacturers, and suppliers with a highlighted global presence. Our main export markets span Asia, Africa, the Middle East, and Europe, leveraging valiant freight and advanced transport services for secure, timely delivery. Sample policies are tailored to customer requirements and order processing is facilitated by experienced logistics teams. Delivery time depends on product specifications and destination, ensuring affordable, reliable, and prompt shipping for every order, whether for single machines or bulk consignments.


FAQ's of QA of Xray Machine:


Q: How does the X-ray machine ensure safety during operation?

A: The X-ray machine is equipped with advanced safety features including an interlock system, emergency stop, built-in protection circuits, LED indicators for power and status, and overheat protection, ensuring a secure imaging environment for users and patients.

Q: What types of connectivity do the X-ray machines support?

A: Connectivity options include USB, LAN, and optional wireless connections, enabling seamless data transfer. The system is also DICOM compatible for easy integration with hospital and clinical information systems.

Q: Where can this X-ray machine be effectively utilized?

A: This versatile equipment is highlighted for use in hospitals, diagnostic centers, veterinary clinics, and various industrial applications thanks to its adaptable mounting options and robust technology.

Q: What benefits does the radiolucent patient table provide?

A: The radiolucent patient table ensures that X-ray images are of eminent clarity and accuracy without artifacts from the table itself, allowing precise diagnostics for a broad range of examination types.

Q: How is the order processed and delivered internationally?

A: Orders are processed promptly upon confirmation with clear sample policy guidelines. We utilize top freight and transport services to ensure reliable delivery, and the shipping schedule is based upon order volume, model selection, and destination.

Q: What is the advantage of automatic image processing and PACS integration?

A: Automatic image processing enhances workflow efficiency and diagnostic quality, while optional PACS integration allows for convenient storage, sharing, and retrieval of patient imaging data across multiple platforms.

  • Minimum Order Quantity
  • 1 Hertz
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Digital X-Ray System Category

Dream Series-Ceiling Suspended

Dream Series-Ceiling Suspended

Minimum Order Quantity : 1 Unit

Power Source : Other, AC Power Supply

Working Voltage : 110V/220V, 50Hz60Hz

Power Consumption : 70150W (Model specific)

Technology : Other, Shadowless LED Technology

Image System : Optional inbuilt camera for recording (on request)

High Powered X-Ray System

High Powered X-Ray System

Minimum Order Quantity : 1 Unit

Power Source : Electric

Working Voltage : 220V/50Hz AC

Power Consumption : 3.5 kW max

Technology : Other, Highfrequency Xray

Image System : Digital capture

High Powered 300mA X-Ray Machine

High Powered 300mA X-Ray Machine

Minimum Order Quantity : 1 Unit

Power Source : Other, Electric, AC supply

Working Voltage : 220V/50Hz

Power Consumption : Less than 3.5 kVA

Technology : Other, High Frequency Digital

Image System : Digital System Supported

AE 100 HF Digital X Ray Machine

AE 100 HF Digital X Ray Machine

Minimum Order Quantity : 1 Unit

Power Source : Electric

Working Voltage : 220V AC

Power Consumption : 6KW

Technology : High Frequency

Image System : Digital Imaging System



Back to top